Avigilon Control Center 5 System Integration Guide with Gallagher Command Centre
9
8. Select the Messages tab.
9. In the FT Controller API strings area, enter the alarm trigger information in the
On field in the following format:
alarmTrigger <Licensed Avigilon Server Address> <Alarm Name>
For example: alarmTrigger 192.168.128.162 burg alarm
NOTE: The case sensitive alarm name is configured in the Avigilon Control Center Client.
See Avigilon Alarm Configuration on page 7 for more information.
10. You have the option of adding an acknowledgement string in the Off field to
automatically acknowledge the alarm in the Avigilon system. Use the following
format:
alarmAck <icensed Avigilon Server Address> <Ack Permission> <Alarm Name>
For example: alarmAck 192.168.128.162 normal burg alarm
NOTE:
<Ack Permission> can be set to normal, grant or deny. The grant and deny
settings can only be used when the alarm requires user confirmation to activate a
digital output. See
Avigilon Alarm Configuration on page 7 for more information.
Alarm monitoring in Avigilon Control Center Client
All alarms configured in the Avigilon Control Center can be monitored in the Avigilon
Control Center Client. See the
Avigilon Control Center Client User Guide for more
information.
Komentarze do niniejszej Instrukcji